layout_sensitive_net_clearance module#

Keep an RF line away from a switch node with a clearance between the tags on two nets.

Use this pattern when a sensitive net needs more room from one noisy net than from everything else. The rule names both tags: design_constraint(RFTag(), NoisyTag()).clearance(RF_TO_NOISY). It applies only between copper carrying the two tags, so the RF line keeps the default spacing to every other net. A rule against AnyObject, such as clearance(RFTag(), AnyObject), pushes everything away, including the coplanar ground an RF line needs (see layout_cpwg_two_row_fence).

The design runs one RF line on layer 0 between two pads 30 mm apart. On its way it crosses two pours on layer 0: a switch-node pour, standing in for a converter’s switch-node copper, and a GND pour. Each pour is split in two by the line, and each half has its own same-net via, so neither half is removed as an island.

Measured on jitx 4.6, building layout_sensitive_net_clearance_design, with a 1.0 mm rule:

  • the switch-node pour stood 1.01 mm from the line’s edge on both sides, the rule plus 0.01 mm;

  • the GND pour stood 0.137 mm from it, the pullback measured on jitx 4.6 from a trace with no clearance rule;

  • both halves of each pour stayed, and the issues listed routing as satisfied.

The NoisyTag sits on the SW net, not on the pour, and the pour took the rule. A tag on a net reaches all of that net’s copper: its traces, pours, code-placed vias and pads. So the same rule applies between the RF line and a switch-node via or pad. This design has two switch-node vias, the pour’s anchors, whose 0.45 mm pads sit about 1.7 mm from the line’s edge, outside the 1.0 mm rule, and no switch-node pad; what it measures is the pour’s voids around the line.

The test, tests/test_layout_sensitive_net_clearance.py, checks the rule and the tags offline. With JITX_PATTERN_RUNTIME=1 and a runtime started at the project root, it builds the design and measures how far each pour pulls back from the line.

RF_TO_NOISY = 1.0#

Clearance between RF copper and switch-node copper, in mm.

LINE_LENGTH = 30.0#

Distance between the RF pads’ centres, in mm.

POUR_SIZE = (8.0, 6.0)#

Each pour’s width and height, in mm.

SW_POUR_X = -6.0#

The switch-node pour’s centre on the line, in mm.

GND_POUR_X = 6.0#

The GND pour’s centre on the line, in mm.

ANCHOR_Y = 2.0#

The pours’ anchor vias sit this far above and below the line, in mm.

class RFTag[source]#

Bases: Tag

Sensitive RF nets.

class NoisyTag[source]#

Bases: Tag

Noisy nets, such as a converter’s switch node.

class RFNearSwitchNode[source]#

Bases: Circuit

An RF line crossing a switch-node pour and a GND pour.

class layout_sensitive_net_clearance_design(*args, **kwargs)[source]#

Bases: SampleDesign

The RF line and the two pours on the sample board.

circuit: Circuit = RFNearSwitchNode()#